IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers

Product Details
Customization: Available
Internal Dimension (W*H*D): 1000*1000*1000mm
External Dimension(W*H*D): 1600*1800*1300mm
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
31
Year of Establishment
2006-10-11
  • IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
  • IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
  • IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
  • IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
  • IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
  • IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
Find Similar Products

Basic Info.

Model NO.
TH series
Temperature Range
-40c to 150c
Humidity Range
20-98% R.H. or Lab Humidity
Test Standard
JIS, ISO, IEC 60529
Transport Package
Export Standard Plywood
Specification
CE certificated
Trademark
ASLi
Origin
Guangdong, China
HS Code
9031809090
Production Capacity
50set/Month

Product Description

25 YZ manufacturer
OEM available
High cost-effective
CE Marked Equipment
SGS tested SUS#304 stainless steel
 
IEC 61215 (MQT 11 12 13)Climatic Solar Panels and Photovoltaic Modules Test Chambers

Brief Introduction for PV Modules test standards:
The designed usage time for solar cell module is about 20~30years , and the reliability test is the simulation of the earth's surface photovoltaic modules (crystalline silicon and amorphous silicon thin film, concentrating) design verification, can let the module long-term operating more than 20 years in a general climate , specification requires that solar cells module do test below :
 
Thermal cycle test;
Humidity-freeze test;
Damp Heat;
 

To confirm the solar cell can withstand high temperature and high humidity level with the minus temperature influence, as well as for repeated change caused by the temperature and thermal fatigue failure, in addition to determine solar cells resistant to moisture long-term penetration ability of the test equipment design and ability to meet the relevant standards below:
(IEC61646 , IEC61416 ,IEC61215 , UL1703 , IEC62108 , IEEE1513 ,IEC61730 etc ) .ower :IEC62108 , IEEE1513
 
Damp Heat :
Condition :temperature 95 ±2 ºC , humidity: 95% ±5% R.H. 
            Testing last for 1000h ,
Purpose:To determine the ability of the module to withstand the effects of long-term penetration of humidity. 
 IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
 
Humidity-freeze test  
Purpose:The purpose of this test is to determine the ability of the module to withstand the effects of high temperature and humidity followed by sub-zero temperatures.
Test points:
low temperature -40ºC,high temperature 85ºC
Max temperature rising speed rate:200ºC/Hour=3.33/min
Max temperature falling speed rate:200ºC/Hour=3.33/min
24 hours per cycle,testing for  10 cycles, 240 hours(10 days)
Temp. Cycle Compare High Temp. High Humidity Low Temp Temp. Change Rate Cycle No.
IEC61215 85ºC/85±5%(20h) -40ºC(0.5~4h) High Temp. Rise& Fall(100ºC/h)
Low Temp. Rise& Fall(200ºC/h)
10
GB9535 85ºC/85±5%(20h) -40ºC(0.5~4h) High Temp. Rise& Fall(100ºC/h)
Low Temp. Rise& Fall(200ºC/h)
10
IEC61646 85ºC/85±5%(20h) -40ºC(0.5~4h) High Temp. Rise& Fall(100ºC/h)
Low Temp. Rise& Fall(200ºC/h)
10
GB18911 85ºC/85±5%(20h) -40ºC(0.5~4h) High Temp. Rise& Fall(100ºC/h)
Low Temp. Rise& Fall(200ºC/h)
10
UL1703 85ºC/85±2.5%(20h) -40ºC(0.5~4h) High Temp. Rise& Fall(100ºC/h)
Low Temp. Rise& Fall(200ºC/h)
10
IEC62108 85ºC/85±2.5%(20h) -40ºC(0.5~4h) High Temp. Rise& Fall(100ºC/h)
Low Temp. Rise& Fall(200ºC/h)
20
40
IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
 
Thermal cycle test;
Test points:low temperature :-40ºC,high temperature:85ºC
Temperature falling/rising speed rate:100ºC/Hour=1.67ºC/min
6 hours per cycle, testing last 50~200 cycles
Total testing time last 300 to 1200 hours (12.5 to 50 days )
 IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
Temp. Cycle Compare Low Temp High Temp Temp Change Rate ºC/h Dwell Time Cycle No.
IEC61215 -40±2ºC 85±2ºC Max. 100ºC/h Min.10min 50, 200
GB9535 -40±2ºC 85±2ºC Max.100ºC/h Min.10min 50, 200
IEC61646 -40±2ºC 85±2ºC Max.100ºC/h Min.10min 50, 200
GB18911 -40±2ºC 85±2ºC Max.100ºC/h Min.10min 50, 200
UL1703 -40±2ºC 90±2ºC Max.120ºC/h 30~105min 200
IEC62108 -40±2ºC 65ºC,85ºC,110ºC 10cycle/day 10min 500,1000,2000
IEC62108 -40ºC 65ºC,85ºC,110ºC 18cycle/day 10min 500,1000,2000
IEEE1513 -40ºC 90ºC,110ºC 0.9~7.5ºC/min Min.10min 250,500
IEEE1513 -40ºC 90ºC,110ºC Max.100ºC/h Min.10min 100,200
IEEE1513 -40ºC 60ºC,90ºC Max.100ºC/h Min.10min 50,200

After-sale service:
Feedback within 2 hours, and offer solution in 48 hours and help to solve the problems.
 
Package: PP film first, and then 10mm foam between machine and the case, and outside is standard export plywood case.
 
Short introduction about ASLi factory:
We are a long history testing equipment manufacturer, in the past 25 years, we devoted to simulation environmental testing equipment and Mechannical vibration and shock testing machine.Walk in stability test chamber  is our star products , and we had obtained the CE certification for this machine.
 IEC 61215 (MQT 11 12 13) Climatic Solar Panels and Photovoltaic Modules Test Chambers
ASLi main test equipments:
Environmental chambers, temperature (humidity) chamber,Thermal shock chamber, PCT /Hast chamber (Highly accelerated stress test chamber),ESS chamber, Walk in stability chamber,Vacuum oven,electrodynamic vibration shaker,mechanical shock tester,environmental combined vibration chamber,etc

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier