Product Parameters
100C to 143C Rubber Aging Testing Chamber Pressure Accelerated Aging Testing Chamber Dimension:
Model: PCT-35
Internal Dimension: 350×450 mm(φ×D)
External Dimension: 800×1260×930mm (W×H×D)
Inner and exterior material with SUS# 304 stainless steel ,or external with powder painted .
Performance:
1. Temp.Range: ( RT+10ºC ) ~ 135ºC Free setting (saturated steam temperature).
2. Humidity Range : 100%RH (default value of saturated steam humidity )
3. Pressure Range: 0.5Kg/cm2 ~ 3.0Kg/cm2 Absolute pressure; (safe pressure capacity 3Kg/cm2 = 1environmental pressure + 2Kg/cm2 )
4. Time Range : 0 ~ 999H / M / S ; optional ; free setting
5. Temp. Uniforminity : (+/-)2.0ºC(100ºC)
6. Temp. Rising Time : ( RT+10ºC ) ~ 120ºC About 45 mins
7. Pressure Time : (Ambient)/ 0.0Kg/cm2 ~ 1.00Kg/cm2 about 45 mins
Product Description
Control System:
1.Micro-computer saturated steam LED digital display temperature controller ,LED
digital time controller and pointer type pressure display gauge. 2. This system complied with high pressure accelerated aging reliability test
standards as : CNS,ISO,JIS,ASTM,DIN.. BS,IEC, NACE,UL,MIL…
3.Control object: micro computer +P.I.D. +S.S.R. Automatic calculating saturated steam temperature .
4. Micro-computer control .
5. Temp. Control Accuracy : (+/-)0.5ºC
6. Resolution : 0.1ºC
7. Pressure control accuracy : (+/-)0.2Kg/cm2
Mechanical Structure:
1.Circular inner box with material of stainless steel, complied with industrial safety standards,able to avoid phenomenon like moisture condensation or water dripping.
2.Inner box with arc type design avoid direct shock caused by over steam temperature.
3. Precision design,good air tightness , low water consumption, automatic water supply and each time able to run for 999h.
4. Automatic door guard, round door with auto temperature and pressure safety check,auto lock the control system. Adopt safety door handle design,when inner pressure larger than normal pressure the door will be anti locked, thus protect the operator .
5. Before testing, the vacuum will help move all the air out of the inner box, and filting, packing<1micom, ensure the purity of the inner box.
6. Critical point LIMIT type auto safety protection, fault or un-normal with light display.
7. The machine with timely drying function, let the testing sample in drying state.
8.Auto and manual water supply;no need to stop the testing ; when testing finished themachine will automatically purging pressure
Detailed Photos
FAQ
1. Are your company a trading one or a factory?
Factory ,28 years focusing on test instruments field,4 years exporting experience.
2. After an order is placed, when to deliver?
Generally about 20 workdays, If we have finished products, we can arrange shipment within 3 workdays.
Please be aware that our production lead times depend on specific items and item quantities.
3. What about the warranty with after - sales services?
12 months warranty.
After the warranty, the professional after-sale service team will provide perfect technical support,and help customer solve problems encountered while using our product, handles guest problems and complaints in a professional and timely.
Exhibition
100C to 143C Rubber Aging Testing Chamber Pressure Accelerated Aging Testing Chamber, Welcome our new and regular customers visit our factory, and any inquiries please feel free to contact us