Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing

Product Details
Customization: Available
After-sales Service: Lifelong Technical Service Support
Power Supply: AC380V
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
31
Year of Establishment
2006-10-11
  • Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
  • Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
  • Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
  • Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
  • Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
  • Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
THR Series
Certification
CE, TUV, ISO
Warranty
1 Year
Temperature Range
-70~+150 Degree C
Humidity Range(Optional)
20%~98%R.H.
Temp. Rising Speed
0.1~3.0degree C/Min
Temp.Falling Speed
0.1~1.5degree C/Min
Analytic Accuracy
0.1degree C; 0.1% R.H
Uniformity
+/-2.5degree C; +/-3.5% R.H.
Control Accuracy
+/-0.5degree C; +/-2.5% R.H.
Cooling System
Water Cooling
Transport Package
Wooden Case
Specification
CE
Trademark
ASLi
Origin
Guangdong, China
HS Code
85141910
Production Capacity
300 Sets/ Year

Product Description

Laboratory Walk In Cyclic Environmental Test Chamber for Damp Heat Testing


Application:

Cyclic Environmental Test Chamber is used to test various types of materials for their tolerances Of heat, cold, dry, humidity. It is applied for quality inspection for all Types of big test samples, Such as electronic products, electric appliance, and products from communication, instrument, Automobile, plastic, metal, food, chemical, building materials, medical and aerospace Industries.
 Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
Product Parameters
Cyclic Environmental Test Chamber Technical Parameters
 Model   THR-volume (low-temperature options : A ~ F)   
 Inner Dimensions(cm)   Customers designated space size and design  
 Temperature Range   Low Temperature(A:25degree C   B:0degree C   C:-20degree C  D:-40degree C  
 E:-60degree C   F:-70degree C ) High Temperature 80degree C  
(80degree C  ~150degree C  is optional) 
 Humidity Range   20%~98%R.H.(10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need 
dehumidifier) 
Indication Resolution/
Distribution Uniformity of 
Temperature & Humidity 
 0.1degree C ; 0.1% R.H/±2.5degree C ; ±3.5% R.H. 
 Control Accuracy of  
Temperature and Humidity 
 ±0.5degree C ; ±2.5% R.H. 
 Temperature Rising/
Falling Velocity
 Temperature rising approx.  0.1~3.0°C/min;
temperature falling approx.  0.3~1.0°C/min;
( The Falling Velocity Min.1.5°C /min is a optional) 
 Cooling System   Water cooled
 Protection Devices   Fuse-free switch, overloading protection switch  for compressor,high and 
low voltage coolant protection switch, over-humidity & over-temperature protection 
switch, fuses,  fault warning system, water short storage warning protection 
 Optional Accessories   Slope for cart , Recorder, Water Purifier, Dehumidifier 
 Compressor   French Tecumseh Brand, Germany Bizer Brand 
 Power   AC 380 V(±10%),50/60HZ ,3 phase  5 Lines 


Cyclic Environmental Test Chamber Features:
1. Graceful appearance, circularly shaped body, surface treated with mist strips and plane Handle with no reaction. Easy to operate, safe and reliable.
2. Rectangular double-paned viewing window for the observation of sample under test With interior lights
3. Double-layer-insulated airtight doors, able to insulate the internal temperature effectively.
4. Water supply system that is externally connectable, convenient for refilling water into The humidifying pot and automatically recyclable.
5. French Tecumseh brand is used as compressor, with environment friendly refrigeration R23, R404A
6. LCD display screen, capable of displaying the set point and actual value at the same Time
7. The control unit has the functions of multiples segment program editing, with ramp rates Control of temperature and humidity.
8. Casters are provided for ease of mobility, with strong positioning screws.
 
Detailed Photos

Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing

Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing


Packing Detail:
Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing
Laboratory Walk in Cyclic Environmental Test Chamber for Damp Heat Testing


If you need more information about Laboratory Walk In Cyclic Environmental Test Chamber for Damp Heat Testing, please feel free to contact us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier