• Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber
  • Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber
  • Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber
  • Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber
  • Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber
  • Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber

Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber

Certification: CE, TUV, ISO
Warranty: 1 Year
Internal Dimension: W600*H500*D500mm
Temperature Range of Testing Zone: Minus 55 Deg to Plus 150deg
High Temperature Range of Testing Zone: 60deg To150deg
Low Temperature Range of Testing Zone: to Under 50deg
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TS-150-B
Exposure Time of High Temperature
+60c to +150c 200c Is Optional
Conversion Time
Less Than 5 Seconds
Volume
150 L
Test Hole
Optional
Communication Interface
R232
Transport Package
Wooden Case
Specification
TS Series
Trademark
ASLi
Origin
Guangdong, China
HS Code
85141910
Production Capacity
300 Sets/Month

Product Description

Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber


Application:

Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber is used to test the capability of material structure or composite materials to withstand the continuous environmental changes between extremely high temperature and low temperature during a short period, and therefore understand the chemical changes or physical damages caused by expansion from heat and contraction from cold in the shortest possible time. It is applicable to metals, plastic, rubber, electronics amongst other materials. The test result can be used as a reference or basis for product improvement. 

Technical Parameters about Thermal Shock Testing Machine:

Model TS-150(A~C)
Internal Dimension WxHxD (mm) 600x500x500
External Dimension WxHxD (mm) 1600x2000x1700
Temperature Range of Testing zone  Type B:-55°C ~+150°C ( 200°C is Optional )
High temperature Range of Testing zone: +60ºC~+150ºC ( 200ºC is Optional);
Low Temperature Range of Testing Zone: -10ºC~-40ºC / -55ºC / -65ºC
Exposure Time of High/ Low Temperature  Exposure Time of High Temperature: +60°C ~ +150°C (200°C is Optional) 30Mins
Exposure Time of Low Temperature : -10°C~Type A:-40°C / Type B -55°C / Type C -65°C 30Mins
Temperature of Heat-Storing Slot / Heating Time RT~200°C/About  45mins
Temperature of Cool-storing Slot / Cooling Time RT~-75°C/ About 100mins
Temperature Recovery Time / Conversion Time ≤5min/≤5sec  
Control Accuracy / Distribution Uniformity ±0.5°C/±2°C
Internal and External Material Material of the inner box is SUS 304# stainless steel,of the outer box is stainless steel or see cold-rolled steel with paint coated.
Insulation Material High temperature resistant , high density , formate chlorine , ethyl acetum foam insulation materials
Mechanics P.I.D+S.S.R+ Micro-computer balanced temperature control system
Cooling System Semi-hermetic double-stage compressor(water-cooled type) /Hermetic double-stage compressor (air-cooled type)
Security Protection Devices Non-fuse breaker, high and low pressure protective switch of the compressor , refrigerator high-pressure protective switch , failure warning system, electronic alarm
Accessories viewing window(special order)
Compressor French 'Tecumseh' Brand, Germany Bizer Brand
Power AC380V 3 phase 5 lines ,50/60HZ
Weight (Approx) 750 Kg

Features with Temperature Cycling Thermal Shock Testing Chamber:
1.Temperature shock test chamber is divided into three boxes: high temperature, low temperature, and the testing area, testing products placed on the testing area; when testing, the valve , which drove by cylinder,lead the high temperature or low temperatures into the testing area. The test sample is in static mode.
2.Using touch-control graph control as operation interface, easy to operate.
3.Applying wind route conversation to the shock method to distribute temperature to the testing zone for cold and thermal shock measurement.
4.For high temperature shock or low temperature shock, maximum time is up to 999H, and maximum circulation cycles are 9999 times.
5.The system can be used for automatic Circulation Shock or manual selective shock.
6.Adopt binary cooling system, with quick cooling effect. Cooling method is water cooling.
7.Can entering normal temperature. R232 and R485 communication interface.

Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber Pictures:
Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber

Programmable Heat Cold Impact Temperature Cycling Thermal Shock Testing ChamberProgrammable Heat Cold Impact Temperature Cycling Thermal Shock Testing ChamberProgrammable Heat Cold Impact Temperature Cycling Thermal Shock Testing ChamberProgrammable Heat Cold Impact Temperature Cycling Thermal Shock Testing ChamberProgrammable Heat Cold Impact Temperature Cycling Thermal Shock Testing Chamber

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now