• 5 Mins Recovery High and Low Temperature Impact Test Chamber
  • 5 Mins Recovery High and Low Temperature Impact Test Chamber
  • 5 Mins Recovery High and Low Temperature Impact Test Chamber
  • 5 Mins Recovery High and Low Temperature Impact Test Chamber
  • 5 Mins Recovery High and Low Temperature Impact Test Chamber
  • 5 Mins Recovery High and Low Temperature Impact Test Chamber

5 Mins Recovery High and Low Temperature Impact Test Chamber

Certification: CE, TUV, ISO
Warranty: 1 Year
Temperature Range: -70~+150 Degree C
Humidity Range(Optional): 20%~98%R.H.
Temperature Recovery Time: Within 5 Mins
Conversion Time: Less Than 5 Seconds
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TS-150-B
Temperature Control Accuracy
+/- 0.5 Degree C
Distribution Accuracy
+/- 2degree C
Compressor
French "Tecumseh" Brand
Viewing Window
Optional
Test Hole
Dia. 50mm
Transport Package
Wooden Case
Specification
150 L
Trademark
ASLi
Origin
Guangdong, China
HS Code
8514109000
Production Capacity
300 Sets/Year

Product Description

5 Mins Recovery High and Low Temperature Impact Test Chamber


Application:

High and Low Temperature Impact Test Chamber is used to test the capability of material structure or composite materials to withstand the continuous environmental changes between extremely high temperature and low temperature during a short period, and therefore understand the chemical changes or physical damages caused by expansion from heat and contraction from cold in the shortest possible time. It is applicable to metals, plastic, rubber, electronics amongst other materials. The test result can be used as a reference or basis for product improvement.
 
Temperature Impact Test Chamber Technical Parameters
Model   TS-42(A~C)  TS-80(A~C)  TS-150(A~C) 
Internal Dimension  
W*H*D ( mm) 
400*350*350  500*400*400  600*500*500 
External Dimension  
W*H*D (mm) 
1400*1800*1400  1550*1950*1550  1600*2000*1700 
Temperature Range 
of Testing zone 
Type A:-40 degree C
~+150degree C
(200degree C is Optional) 
Type B:-55degree C ~
+150degree C  
(200degree C is Optional) 
   High temperature Range of Testing zone: 
+60degree C~+150degree C(200degree C is Optional); 
Low Temperature Range of Testing Zone: -10degree C~-40degree C/
-55degree C/-65degree C 
Exposure Time of 
High/Low Temperature 
Exposure Time of High Temperature:+60degree C~+150degree C
(200degree C is Optional)  30Mins 
  Exposure Time of Low Temperature:-10degree C~Type A:-40degree C/ 
Type B -55degree C/ Type C -65degree C  30Mins 
Temperature of 
Heat-Storing Slot/
Heating Time  
RT~200degree C/About  45mins 
Temperature of
 Cool-storing Slot/
Cooling Time 
RT~-75degree C/ About 100mins 
Temperature 
Recovery Time/  
Conversion Time 
≤5min/≤5sec  
Control Accuracy /  
Distribution Uniformity   
±0.5degree C/±2degree C 
Internal and Externa
l Material 
Material of the inner box is SUS 304# stainless steel,of the outer box  is stainless steel or SEE cold-rolled steel with paint coated. 
Insulation Material  High temperature  resistant, high density, formate chlorine, ethyl acetum foam insulation materials  
Mechanics  P.I.D+S.S.R+ Micro-computer balanced temperature control system 
Cooling System  Semi-hermetic double-stage compressor(water-cooled type) /Hermetic double-stage compressor (air-cooled type) 
Security Protection
 Devices 
Non-fuse breaker, high and low pressure protective switch of the compressor , refrigerator  high-pressure protective switch, failure warning system, electronic alarm 
Accessories  Viewing window(special order) 
Compressor  French "Tecumseh" Brand, Germany Bizer Brand 
Power  AC220V 1 phase  3 lines,50/60HZ, AC380V 3phase  5 lines,50/60HZ 
Weight (Approx)  450  600                    750 


Features:
1. It is divided into three zones: High temperature zone, low temperature zone, and testing zone. The test sample is in static mode.
2. Using touch-control graph control as operation interface, easy to operate.
3. Applying wind route conversation to the shock method to distribute temperature to the testing zone for cold and thermal shock measurement.
4. For high temperature shock or low temperature shock, max. Time is up to 999H, and max. Circulation cycles are 9999 times.
5. The system can be used for automatic Circulation Shock or manual selective shock.
6. Adopt binary cooling system, with quick cooling effect. Cooling method is water cooling.
7. Can entering normal temperature. RS-232 and RS-485 communication.
5 Mins Recovery High and Low Temperature Impact Test Chamber
5 Mins Recovery High and Low Temperature Impact Test Chamber 5 Mins Recovery High and Low Temperature Impact Test Chamber

For the package:
1. PP film first
2. Vacuum package
3. PP film again
4. 10mm thickness PU foam to avoid collision
5. stronged plywood case
6. Standard ASLI CASE MARK

5 Mins Recovery High and Low Temperature Impact Test Chamber
Saftey device:
1. With no-fuse protection switch
2. Control system with phase sequence protection and low voltage electrical protection.
3. With over-heat protection switch.
4. Over load protection device for refrigeration compressor.
5. Refrigeration compressor high and low voltage protection switch.
6. Refrigeration compressor over oil pressure protection.


If you have any doubt about 5 Mins Recover High and Low Temperature Impact Test Chamber, please feel free to contact us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now