Product Description
Corresponding standard
1 GB/T2423.1-1989 low-temperature testing method
2 GB/T2423.2-1989 high-temperature testing method
3 GB/T2423.22-1989 change temperature test
4 GJB150.5-86 temperature impact test
5 GJB360.7-87 temperature impact test
6 GJB367.2-87 405 temperature impact test
Product Description
High Low Temperature Fast Change Thermal Shock Chamber for Lighting used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time, Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is high-temperature region, another is low-temperature region, the testing sample placed on the moving basket, using unique heat storage and cool storage,the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing; applied to test the material, including metal, plastic, rubber, electronics ....and other materials, it can be used as a basis for improvement of their products.
Product Parameters
Name
|
Thermal Shock Test Chamber
|
Mode
|
TS-49(A~C)
|
TS-80(A~C)
|
TS-150(A~C)
|
Internal Dimension WxHxD (mm)
|
400x350x350
|
500x400x400
|
600x500x500
|
External Dimension WxHxD (mm)
|
1400x1800x1400
|
1550x1950x1550
|
1600x2000x1700
|
Temperature Range of Testing zone
|
Type A:-40 ºC~+150ºC ( 200ºC is Optional)
|
Type B:-55ºC ~+150ºC ( 200ºC is Optional )
|
Type C:-65ºC ~+150ºC ( 200ºC is Optional)
|
Control Accuracy / Distribution Uniformity
|
±0.5ºC/±2ºC
|
Internal and External Material
|
Material of the inner box is SUS 304# stainless steel,of the outer box is stainless steel or see cold-rolled steel with paint coated.
|
Insulation Material
|
High temperature resistant , high density , formate chlorine , ethyl acetum foam insulation materials
|
Thermal Shock Chamber Features:
1.It is divided into three zones: high temperature zone, low temperature zone, and testing zone. The test sample is in static mode.
2.Using touch-control graph control as operation interface, easy to operate.
3.Applying wind route conversation to the shock method to distribute temperature to the testing zone for cold and thermal shock measurement.
4.For high temperature shock or low temperature shock, max. time is up to 999H, and max. circulation cycles are 9999 times.
5.The system can be used for automatic Circulation Shock or manual selective shock.
6.Adopt binary cooling system, with quick cooling effect. Cooling method is water cooling.
7.Can entering normal temperature. RS-232 and RS-485 communication.
Detailed Photos
Packaging & Shipping
1. PP film first
2. Vacuum package
3. PP film again
4. 10mm thickness PU foam to avoid collision
5. stronged plywood case
6. Standard ASLI CASE MARK
7. Ship worldwide
Company Profile
We are a long history testing equipment manufacturer, in the past 25 years, we devoted to simulation environmental testing equipment and Mechannical vibration and shock testing machine.Programmable High and Low Temperature Thermal Shock Chamber for Lighting is our star products, and we had obtained the CE certification for this machine.
Customers' Visit ASLi
Our service
1.High quality guarantee.
2.Shipment with professional documents.
3.Packing as your request, with photo before shipment.
4.Reply within 48 hours and provide solution within 3 working days
5.Professional after-service from our engineers.
6.Warranty period 12 monthes.
Our advantages
1.Professional technology support.
2.Full experience of large numbers containers loading in Chinese sea port.
3.Fast shipment by reputed shipping line.
4.Best service after shipment with emails.
5.We are professional test equipment manufaturer in China with excellent experience and skills, also have best quality products
FAQ
1. Are your company a trading one or a factory?
Factory ,28 years focusing on test instruments field,4 years exporting experience.
2. After an order is placed, when to deliver?
Generally about 20 days, If we have finished products, we can arrange shipment within 3 days.
Please be aware that our production lead times depend on specific items and item quantities.
3. What about the warranty with after - sales services?
12 months warranty.
After the warranty, the professional after-sale service team will provide perfect technical support,and help customer solve problems encountered while using our product, handles guest problems and complaints in a professional and timely.
4. What about the services and product' quality?
Each instruments must be carried out 100% quality examination and test, the finished products must through a third party calibration institutions before shipping and delivery goods.
If you have any relative inquiries about High Low Temperature Fast Change Thermal Shock Chamber for Lighting, please don't hesitate to contact us.