Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test

Product Details
Customization: Available
After-sales Service: Lifelong Technical Service Support
Warranty: 1 Year
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
31
Year of Establishment
2006-10-11
  • Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
  • Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
  • Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
  • Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
  • Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
  • Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
THV-408
Max Diameter of Workpiece
>3200mm
Mass Scope of Workpiece
4000kg
Type
Vibration Testing Machine
Display
Digital
Control
Computer Control
Power Source
AC380V
Oil Cylinder Position
Under
Sine Force Peak
57.8 Kn
Max Random Force RMS
66.0 Kn
Velocity Sine Peak
1.8 M/S
Displacement Continous Pk-Pk
63.5 mm
Usable Frequency Range
DC – 2.5 kHz
Transport Package
Poly Case Box
Specification
can be customized
Trademark
ASLI
Origin
China
HS Code
90318090
Production Capacity
10set/Month

Product Description

Product Description

When necessary to considering of high or low temperature environment at the same time of vibration.  It recommanded Temperature Humidity Combined Vibration Shaker Chamber


Temperature Humidity Combined Vibration Shaker Chamber Application:

>For automotive parts and systems, including Hot Shake Test (HST) of brake and exhaust systems, Squeak and Rattle tests, Road Load Data applications, ISO/TS16949 and other industry standards.
>For electronic assembly and computer equipment testing
>For avionics hardware testing, such as Mechanical Environmental Tests AECTP 400, ISO 9000, MIL-STD, AS9000, and RTCA DO-160 Section 8 tests
>For telecommunication and satellite component testing
>For general stress screening, including ISO 5344, Accelerated Durability Testing (ADT), HALT and HASS
>For product and package testing, such as ISTA and ASTM 4169 tests
>For shock test applications, including Shock Response Spectrum (SRS)
>For environmental testing with AGREE chambers, Combined Environmental Reliability Test (CERT) and others


Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
Temperature Humidity Combined Vibration Shaker Chamber Standard models:
How to choose a proper size of environment chamber:
The test zone should at least 150mm bigger than Maximum size of the test sample from right, left and top.

 
Product Parameters
Model  THV-408(A~F)  THV-1000(A~F)  THV-1500(A~F)
Internal Dimension 
W×H×D(mm) 
600×850×800  1000×1000×1000  1500×1500×1500
External Dimension 
W×H×D(mm) 
850×1950×2100  1300×2200×2400  1800×2400×3000
Temperature Range  Low temperature: (A:25degree; B:0degree; C:-20degree ; D: -40degree; E: -60degree; F: -70degree) 
High temperature:100degree(150degree)
Humidity Range  20%~98%relative humidity(10%-98% relative humidity / 
5%-98% relative humidity is a special optional condition, need Dehumidifier) 
Analytic Accuracy / 
Distribution uniformity
 of temperature
 and humidity 
0.1degree; 0.1% relative humidity/±2.0degree; ±3.0% relative humidity 
Control Accuracy of 
temperature and humidity 
±0.5degree; ±2.5% relative humidity 
Temperature Rising
 / Falling Speed Rate 
Temperature rising approx.  0.1~3.0degree/min / 
temperature falling approx.  0.1~1.5degree/min;
(The Falling Speed Rate Min.1.5degree/min is a special optional condition) 
Internal and External Material   inner box is SUS 304# stainless steel,  outer box is stainless steel or SEE cold-rolled steel with paint coated. 
Insulation Material  Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials 
Cooling System  Wind cooling or water cooling/single segment compressor (-40degree, double segment compressor -70degree) 
Protection Devices  Fuse-free switch, overloading protection switch  for compressor,high and low voltage coolant protection 
switch, over- humidity and over-temperature protection switch, fuses, fault warning system,  water short storage warning protection 
Optional Accessories  Inner door with operation hole(Optional) , Recorder(optional), Water Purifier, Dehumidifier 
Vibration Test Equipment  Choose a proper vibration system for solution, 
Power  AC380V 3ph  5 Lines, 50/60HZ 

Temperature Humidity Combined Vibration Shaker Chamber choose vibration and bench table:
Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test


How to choose the suitable Shaker with enought Shaker force.  
 Desired Force = MAX1.3X10
Mass (M)
in kgs
Acceleration (A)   1.3 is considering of Allowance 1KG=10N

Mass included:
Test Specimen Mass,
Specimen Interface Fixture Mass, 
Armature Mass:
Head Expander Mass:
Associated Mounting Hardware (Estimate):


Below our available standard models for optional:

Vertical Bench:
Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test

The bench tabel should be proper size to carry for the max size of your test samples.
The center of gravity of the sample should be centered.
The bench table Frequency is inversely proportional to weight.

Horizental Bench:
Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test

Temperature Humidity Combined Vibration Shaker Chamber Features:

>  A combined structure of test chamber and refrigerating system boasting compact and graceful design; Independent console
> To make it convenient for operation; Original refrigerating compressor unit and its main accessories imported from abroad
> Imported LCD color touch screen controller capable of automobile control of temperature humidity programs;
>With R232 Telecommunication interface. To meet customer's unique demands, users may choose from different models of vibration test bench to ensure that in addition to good cool
> Heat and air seal system, this vibration bench will also boasts remarkable effect of mechanical vibration
Detailed Photos
Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test
Packaging & Shipping

Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum TestTemperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test


Warranty:  One year free warranty for whole set machine, lifelong time maintainance.

if you need a quote or any information about Temperature Humidity Combined Vibration Shaker System Chamber for Shock Response Spectrum Test, pls don't hesitate to get in touch.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier