| Customization: | Available |
|---|---|
| After-sales Service: | Lifelong Technical Service Support |
| Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
When necessary to considering of high or low temperature environment at the same time of vibration. It recommanded Temperature Humidity Combined Vibration Shaker Chamber
| Model | THV-408(A~F) | THV-1000(A~F) | THV-1500(A~F) | |
| Internal Dimension W×H×D(mm) |
600×850×800 | 1000×1000×1000 | 1500×1500×1500 | |
| External Dimension W×H×D(mm) |
850×1950×2100 | 1300×2200×2400 | 1800×2400×3000 | |
| Temperature Range | Low temperature: (A:25degree; B:0degree; C:-20degree ; D: -40degree; E: -60degree; F: -70degree) High temperature:100degree(150degree) |
|||
| Humidity Range | 20%~98%relative humidity(10%-98% relative humidity / 5%-98% relative humidity is a special optional condition, need Dehumidifier) |
|||
| Analytic Accuracy / Distribution uniformity of temperature and humidity |
0.1degree; 0.1% relative humidity/±2.0degree; ±3.0% relative humidity | |||
| Control Accuracy of temperature and humidity |
±0.5degree; ±2.5% relative humidity | |||
| Temperature Rising / Falling Speed Rate |
Temperature rising approx. 0.1~3.0degree/min / temperature falling approx. 0.1~1.5degree/min; (The Falling Speed Rate Min.1.5degree/min is a special optional condition) |
|||
| Internal and External Material | inner box is SUS 304# stainless steel, outer box is stainless steel or SEE cold-rolled steel with paint coated. | |||
| Insulation Material | Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials | |||
| Cooling System | Wind cooling or water cooling/single segment compressor (-40degree, double segment compressor -70degree) | |||
| Protection Devices | Fuse-free switch, overloading protection switch for compressor,high and low voltage coolant protection switch, over- humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection |
|||
| Optional Accessories | Inner door with operation hole(Optional) , Recorder(optional), Water Purifier, Dehumidifier | |||
| Vibration Test Equipment | Choose a proper vibration system for solution, | |||
| Power | AC380V 3ph 5 Lines, 50/60HZ | |||
| Desired Force = MAX1.3X10 | ||||||
| Mass (M) in kgs |
Acceleration (A) | 1.3 is considering of Allowance | 1KG=10N | |||
| Test Specimen Mass, |
| Specimen Interface Fixture Mass, |
| Armature Mass: |
| Head Expander Mass: |