Customization: | Available |
---|---|
Certification: | CE, TUV, ISO |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Walk in Temperature Humidity Test Room Technical Parameters | |
Model | THR-volume (low-temperature options : A ~ F) |
Inner Dimensions(cm) | Customers designated space size and design |
Temperature Range | Low Temperature(A:25degree C B:0degree C C:-20degree C D:-40degree C E:-60degree C F:-70degree C ) High Temperature 80degree C (80degree C ~150degree C is optional) |
Humidity Range | 20%~98%R.H. (10%-98% R.H. / 5%-98% R.H ,is a special optional condition, need dehumidifier) |
Indication Resolution/ Distribution Uniformity of Temperature & Humidity |
0.1degree C ; 0.1% R.H/±2.5degree C ; ±3.5% R.H. |
Control Accuracy of Temperature and Humidity |
±0.5degree C ; ±2.5% R.H. |
Temperature Rising/ Falling Velocity |
Temperature rising approx. 0.1~3.0°C/min; temperature falling approx.0.3~1.0°C/min; ( The Falling Velocity Min.1.0°C /min is a optional) |
Cooling System | Water cooled |
Protection Devices | Fuse-free switch, overloading protection switch for compressor,high and low voltage coolant protection switch, over-humidity & over-temperature protection switch, fuses, fault warning system, water short storage warning protection |
Optional Accessories | Slope for cart , Recorder, Water Purifier, Dehumidifier |
Compressor | French Tecumseh Brand, Germany Bizer Brand |
Power | AC 380 V(±10%),50/60HZ ,3 phase 5 Lines |
Optional accessories | |
1 | Cable Port: Two size of cable port is available: Φ50mm, Φ100mm. |
2 | Double door |
3 | Pass room: Provided to avoid disturbance of atmospheric temperature and humidity while opening the door. |
4 | Floor reinforcement: Can be fixed if heavy specimen placed in the chamber for test. |
5 | Carry-in inclined platform: Provided below the door to facilitate moving of specimens in and out through the door. |
6 | Entire ceiling blow-out duct |
7 | The extremely wide air inlet reduces the airflow rate (down to apprrox.0.5m/s) |
8 | Dehumidifier |
9 | The rotation regenerating dehumidifier (M-300)ensures precise control of low humidity (21 C,23%RH)for electrostatic reliability tests. |
10 | Temperature and humidity recorder |
11 | 100mm width recording paper with 6 dots |
12 | 180mm width recording paper with 12 dots |
13 | Status indication lamp |
14 | Provide to signal chamber status and warnings when normal running, a malfunction running or stand by occurs. |
15 | Water purifier |
16 | Provided to keep the humidifier heater free from scale and ensure the supply of water to humidifier. |
17 | Power socket |