• High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard
  • High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard
  • High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard
  • High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard
  • High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard
  • High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

After-sales Service: Lifelong Technical Service Support
Power Supply: AC380V
Certification: CE, TUV, ISO, SGS BV
Warranty: 1 Year
Moving Coil Size: Dia. 150 mm
Vibration Wave: Sine, Random, Shock
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
Overview

Basic Info.

Model NO.
ES-10
Frequency Range
1Hz to 3500Hz
Max. Acceleration
1000m/S2
Max. Speed
2.0m/S
Impact Displacement
51mm
Moving Coil Weight
6.5kg
Transport Package
Wood Export Case
Specification
Customized
Trademark
ASLI
Origin
China
HS Code
85141090
Production Capacity
500sets Per Month

Product Description

Product Description

Application of Electromagnetic Frequency-sweep Vibration Test

High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard adopted the 'double-magnetic circuit structure','self-generated skeleton action circles', 'Airborne Support' and 'roller bearings and linear guidance','trunnion isolation' advanced modern technology and special technology, can be completed in X, Y, Z three-axis sinusoidal vibration test and broadband random vibration tests, to be completed by the classical (half - sine, trapezoidal, sawtooth wave) pulse and shock response spectrum test. It widely used in national defense, weapons, aviation, aerospace, communications, electronics, electrical appliances, communications, home appliances and other fields.

High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

Product Parameters
Technical sheet about Vertical and Horizontal Vibration Tester
Model Rated Sine Force (N) Rated Random Force (N) Frequency Range (Hz) Rated Acceleration (m/s2) Rated Speed (m/s) Rated displacement (p-p)mm Max. Loading (Kg) moving coil (Kg) Dimension of Moving coil (mm)
ES-3 3000 3000 3-3500 1000 1.6 25 100 3.5 Φ150
ES-3a 3000 3000 3-3500 400 1.6 40 120 9 Φ230
ES-6 6000 6000 3-3500 1000 1.6 25 180 6.5 Φ230
ES-6a 6000 6000 3-3500 1000 1.6 51 250 12 Φ230
ES-10 10000 10000 3-3000 1000 1.8 51 270 14 Φ240
ES-20 20000 20000 3-3000 1000 1.8 51 300 30 Φ320
ES-30 30000 30000 3-2800 1000 1.8 5l 450 40 Φ450
ES-40 40000 40000 3-2800 1000 1.8 51 500 50 Φ450
ES-50 50000 50000 3-2700 1000 1.8 51 750 50 Φ450
Detailed Photos

High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test StandardHigh Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

For Vertical Expander

VT vertical extended-bench and specified clamps, precision calculated, elaborate design, to ensure the customer acquired the best performance according to perfect structure, high quality material and workmanship.
High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

For Horizontal Expander

Within small loading bench to realize higher acceleration and working frequency, to improve the loading capacity and performance of whole machine bench.

Horizontal bench and vibration bench are integral type, with perfect structure, convenience to install and adjust.

Static pressure track, V-shape, with capacity of slope-resistant and bias-loading resistant.

Built-in oil pump, good structure and easy operating.
High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

Install Requirement

(1)Users should prepare forklifts & shifting tools for moving the equipment as it is very heavy, also please be sure the door is big enough to let in the equipment

(2)The operating environment of the machine should be under room temperature and with good ventilation.

We strongly suggest to install air conditioner in the working area. The space distance of the machine's

left/right/back side must be Min. 700mm, the front must be Min. 1500mm.


Company Information

We are a long history testing equipment manufacturer, in the past 25 years, we devoted to simulation environmental testing equipment and Mechannical vibration and shock testing machine.High Frequency Electrodynamic Vibration Shaker For Test Standard of ISO 16750-03, IEC 60068-2 is our star products, and we had obtained the CE certification for this machine.
High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard

Welcome our new and regular customers visit our factory with High Frequency Electrodynamic Vibration Shaker Table for ISO 16750-03, IEC 60068-2 Test Standard, and any inquiries please feel free to contact us 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now